Classifying views and laterality to support hanging protocols and the organisation of mammography images.
My role
Developed the classification tool
Focus
Computer vision · Radiology workflows
My contribution.
What I built
The view and laterality classification tool, from acquisition metadata and image evidence to display instructions.
How it works
The tool works on a copy, checks side consistency and returns labels only when verification conditions are met.
Context.
An imaging workflow depends on knowing what each image represents. View and laterality labels help organise a mammography study into a useful reading layout.
My approach.
I developed a classification tool that combines acquisition metadata and image evidence to identify mammography view and laterality. It prepares a working copy, checks side consistency and returns classification information with display instructions when the verification conditions are met. Original image pixels remain unchanged.
Prepare a working copy
Combine metadata and image evidence
Verify side consistency
Return labels and display instructions
Project considerations.
Reviewing weaker classes and unexpected inputs helps identify where more data or a different classification approach is needed.
Schematic study · prepared classifications
Try the reading workflow.
MG · prepared exampleReceived
From images to reading order
Four schematic views, received in a mixed order.
Image AOriginal preserved
Select a view, then follow the example into a reading layout.
How the workflow works7 stages
A DICOM image arrives
The integration supplies pixels and acquisition metadata. These four views are synthetic illustrations.
Image pixelsAcquisition metadata
1 of 7
Prepared example · no live inference. Labels and display instructions are illustrative.
1 min 35 sec
Follow the mammography classification workflow.
Conceptual walkthrough supplied by Olivia, with example data and illustrative results. Playback starts when you choose.
Read the workflow description
Acquire
An integration supplies a DICOM image with its pixels and acquisition metadata. The workflow covers 2D mammography and tomosynthesis.
Prepare
A working copy is normalized, cropped to the breast region, then resized and padded to 1024 × 1024. The original stays unchanged. The illustrated tomosynthesis path uses the first frame for the main prediction.
Analyze
Acquisition metadata and image pixels provide complementary evidence about side and view. The diagram shows the two evidence paths, without specifying their execution timing.
Combine
The outputs and acquisition context contribute to the combined side and view prediction, confidence information and review flags. The displayed predictions are illustrative.
Verify
The predicted side is checked against the recorded side. The tomosynthesis example also checks sampled frames, using targeted fallback checks when mask comparisons fail. Its example values are not a performance evaluation.
Return and display
Classification results inform a Presentation State. A compatible viewer receives original pixels separately and applies the display instructions. The illustrated image needs no rotation or flip.
Complete
Missing side information follows an inference and confidence check. Conflicting side information is preserved and flagged for review. If the gate declines, classification results return without display instructions.